IQAir PreMax MG Filter

In stock - same day dispatch
Buy now in 4 instalments with Pay with Klarna

  • Combination of Particle, Gas & Odour Filter
  • For use with HP 150
  • Efficiency: 55% at 0.3 μm (class F8)
  • Filter Life: 12 -18 months (average usage)
  • Filter Number: F1
  • Art. Number: 102 10 20 00

The PreMax MG Filter is a particle filter combined with a gas and odour filter for the HealthPro 150. The PreMax MG Filter filters out coarse and fine particulate matter. This is important for protecting the fan motor and significantly prolonging the life of the subsequent filters.

Allergens
  • Hay-Fever
  • Pet Allergens (cat, dog, horse etc.)
  • Pollen
  • Dust Mite Allergens
Odours
  • Pet Dander (cats, dogs etc.)
  • Cooking Odours
  • Musty Smells
Gases & Fumes
  • Paints
  • Varnishes
  • Adhesives
  • Formaldehyde
  • Building Materials
City Pollution
  • Smog
  • Transportation (cars, trains, planes)
  • Industry Pollution
  • Other Volatile Organic Compounds

Microorganisms
  • Bacteria
  • Viruses
  • Fungal Spores
Tobacco Smoke
  • Smoke Chemicals
  • Smoke Particles


Pre-Filter Stage:

  • Purpose: control of coarse and fine particulate matter; protection of subsequent filters
  • Filter Number: F1
  • Media: non-woven glass microfiber, mini-pleated for high-capacity
  • Efficiency: 55% at 0.3 μm (class F8)
  • Surface area of particle filter :1.9 m2 / 20.5 sf
  • Dimensions: H 33 x W 33 cm; H 13 x 13 inches
  • Amount of Activated Carbon:1 kg / 2.2 lbs

Gas- & Odour Filter Stage:

  • Purpose: control of a wide range of chemical contaminants and odours
  • Media: MultiGas activated carbon & impregnated activated alumina
  • Weight: 1.0 kg / 2.2 lbs
  • Efficiency: absorbs a wide array of gaseous pollutants and odours
  • Filter Life: 6-18 months
  • Country of Manufacture: Switzerland
  • Art. Number: 102 10 20 00

The PreMax Pre-Filter stage captures pollen, pet, dust mite and mould allergens, protecting the fan and subsequent filters from large particle pollution and premature loading.

The PreMax Gas- & Odour Filter stage provides the best solution for gas and odour elimination.

1. Micro-Particle Filtration 
The PreMax MG Filter captures pollen, pet, dust mite and mould allergens. 
The Pre-Filter consists of a pre-filter stage made from a high-capacity mini-pleat design. The media of the filter is a wet laid non-woven glass microfiber and has an efficiency of 55% at 0.3 μm (class F8).

2. Odour and Gas Elimination 
The Pre- and Gas-filter stages are combined together in the PreMax MG Filter. The Gas-filter stage eliminates Volatile Organic Compounds (VOCs), and destroys harmful chemicals, such as formaldehyde. The media consists of a MultiGas granular activated carbon & KMnO4 impregnated alumina - the most effective material to filter out a broad spectrum of gases, chemicals and odours.

The large surface area of the PreMax MG Filter protects the fan and HyperHEPA filter from large particle pollution and premature loading.

The PreMax MG Filter is a particle filter combined with a gas and odour filter for the HealthPro 150. The PreMax MG Filter filters out coarse and fine particulate matter. This is important for protecting the fan motor and significantly prolonging the life of the subsequent filters.

Allergens
  • Hay-Fever
  • Pet Allergens (cat, dog, horse etc.)
  • Pollen
  • Dust Mite Allergens
Odours
  • Pet Dander (cats, dogs etc.)
  • Cooking Odours
  • Musty Smells
Gases & Fumes
  • Paints
  • Varnishes
  • Adhesives
  • Formaldehyde
  • Building Materials
City Pollution
  • Smog
  • Transportation (cars, trains, planes)
  • Industry Pollution
  • Other Volatile Organic Compounds

Microorganisms
  • Bacteria
  • Viruses
  • Fungal Spores
Tobacco Smoke
  • Smoke Chemicals
  • Smoke Particles


Pre-Filter Stage:

  • Purpose: control of coarse and fine particulate matter; protection of subsequent filters
  • Filter Number: F1
  • Media: non-woven glass microfiber, mini-pleated for high-capacity
  • Efficiency: 55% at 0.3 μm (class F8)
  • Surface area of particle filter :1.9 m2 / 20.5 sf
  • Dimensions: H 33 x W 33 cm; H 13 x 13 inches
  • Amount of Activated Carbon:1 kg / 2.2 lbs

Gas- & Odour Filter Stage:

  • Purpose: control of a wide range of chemical contaminants and odours
  • Media: MultiGas activated carbon & impregnated activated alumina
  • Weight: 1.0 kg / 2.2 lbs
  • Efficiency: absorbs a wide array of gaseous pollutants and odours
  • Filter Life: 6-18 months
  • Country of Manufacture: Switzerland
  • Art. Number: 102 10 20 00

The PreMax Pre-Filter stage captures pollen, pet, dust mite and mould allergens, protecting the fan and subsequent filters from large particle pollution and premature loading.

The PreMax Gas- & Odour Filter stage provides the best solution for gas and odour elimination.

1. Micro-Particle Filtration 
The PreMax MG Filter captures pollen, pet, dust mite and mould allergens. 
The Pre-Filter consists of a pre-filter stage made from a high-capacity mini-pleat design. The media of the filter is a wet laid non-woven glass microfiber and has an efficiency of 55% at 0.3 μm (class F8).

2. Odour and Gas Elimination 
The Pre- and Gas-filter stages are combined together in the PreMax MG Filter. The Gas-filter stage eliminates Volatile Organic Compounds (VOCs), and destroys harmful chemicals, such as formaldehyde. The media consists of a MultiGas granular activated carbon & KMnO4 impregnated alumina - the most effective material to filter out a broad spectrum of gases, chemicals and odours.

The large surface area of the PreMax MG Filter protects the fan and HyperHEPA filter from large particle pollution and premature loading.